Key data

Container20HC, 30HC or 40HC
Full energy3.65MWh, 6.02MWh or 7.53MWh
Available energy2.67~7.53MWh by container
Voltage1000V-1500V

Abstract

Read energy storage portable specs for a centralized energy storage system by container format, energy, voltage, operating conditions, protection, communication and lifecycle figures. The guide connects each parameter to a practical ordering check.

Energy storage portable specs: how to read a centralized system sheet
Illustration for reference; see the product page for actual photos and specifications.
§1

Start with the container format

For energy storage portable specs, start with the container format because it sets the system footprint and the energy figures you will compare. Our centralized energy storage system is specified in 20HC, 30HC and 40HC formats, with different full energy, available energy and size values.

Parameter20HC30HC40HC
Full Energy3.65MWh6.02MWh7.53MWh
Available Energy2.67~3.65MWh4.52~6.02MWh6.67~7.53MWh
Sizes605824382896mm912524382896mm1219224382896mm
Full Configuration Weight28T28T28T

Full energy is the system's stated energy figure for the selected format. Available energy is the stated usable range. Use the available-energy row when matching the system to an energy requirement, and require the quotation to identify the selected container format and final configuration.

Size and full configuration weight affect transport planning, foundation preparation and access to the installation area. Measure the route, clearance and support area against the selected size before ordering. Confirm whether the 28T full configuration weight applies to the configuration you are buying.

§2

Read voltage and power rate together

The voltage range is 1000V-1500V, and the charge/discharge ratio is 0.5CP. Voltage identifies the system's operating electrical range. The charge/discharge ratio describes the stated rate for charging and discharging relative to the system capacity.

Include both values in the electrical review. Give the supplier the site-side voltage requirements and intended charge and discharge profile, then require the selected values to appear in the order documents.

§3

Check the cell and module entries

The cell entry is LFP-3.2V-280Ah-896Wh. It combines the LFP cell type with the stated voltage, ampere-hour rating and watt-hour figure. The module entries are LFP-38.4V-560Ah-21.504kWh/LFP-76.8V-280Ah-21.504kWh.

These lines help you compare the proposed battery architecture and understand how the stated energy is assembled. Confirm which module entry belongs to the selected configuration, and keep the cell and module descriptions unchanged in the purchase specification.

§4

Interpret lifecycle and efficiency figures

Cycle life is 8000 cycles (90% DOD, ≥70% EOL). The condition matters: the figure is tied to 90% DOD and an end-of-life level of ≥70% EOL. Cyclic efficiency is ≥94% (DC side), which identifies the side of the system to which the efficiency figure applies.

Use these values when comparing operating plans and lifecycle expectations. Require the order documents to carry the same DOD, EOL and DC-side wording, rather than comparing the cycle number or efficiency symbol alone.

§5

Review control, cooling and protection

The BMS program is Active equalization + 3-tier architecture. The communication interfaces are Ethernet/RS-485/CAN, and the communication protocols are Modbus-TCP/IEC61850/104. These entries define how the battery management system communicates and how the system can connect with site controls.

Temperature control is Intelligent variable frequency air cooling. The firefighting program includes gas, smoke and temperature detection, HFC227, water fire fighting, optional C6F12O and active ventilation. Confirm the interface list, protocol requirement and firefighting configuration with your electrical and safety teams before the order is finalized, including whether the optional C6F12O item is required.

§6

Confirm site environment and enclosure values

The altitude is ≤5000m (>3000m Derating), the temperature range is -40 to 55℃, and humidity is 0-95% Rh (Non-condensing). Protection grade is IP65, and anti-corrosion grade is C4 (C5 optional).

Compare these values with the installation site. Confirm site altitude, temperature, humidity and corrosion exposure, then state the required protection and anti-corrosion grades in the order documents. If the site is above 3000m, include the stated derating condition in the technical review.

§7

Check auxiliary power, insulation and certifications

Auxiliary power is AC380V-50Hz, and insulation resistance is >10MΩ. Auxiliary power is the supply requirement for supporting system functions. Insulation resistance is an electrical property to include in the technical review and acceptance discussion.

The certification line identifies the standards and tests relevant to the selected configuration. Match the applicable entries to market and project requirements in the quotation request, and require the selected certification set to be identified.

Reading tip

Match available energy and container size to the project first. Then compare voltage, charge/discharge ratio, site conditions, protection, communication, firefighting options and the exact lifecycle conditions in the order documents.

Prepare the order review

Put the selected container format, required available energy, site electrical requirements, installation environment and communication interface requirements in the inquiry. Require the commercial and technical documents to repeat the selected specification lines before the order is finalized.

The company

Suzhou ACDC New Energy Technology Co., LTD.,

Suzhou ACDC New Energy Technology Co., LTD., headquartered in Suzhou High-tech Zone, is a leadinglithium energy storage system provider from China. As a team with decades of experiences on thermalmanagement system, outdoor cabinet design, battery management system and energy managementsystem through loT technology, we are committed to the integration of loT and clean energy revolution.…

About Us ↗Visit company website ↗

Next:

This is the last article

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.